Pengaruh Jarak Outlet Ventilasi Udara Terhadap Gas Metan Pada Tunnel Tambang Bawah Tanah

  • Bonar Sari Monang Naibaho Institut Sains Dan Teknologi TD.Pardede
  • Efa Octavia Jawak Institut Sains Dan Teknologi TD.Pardede
  • M. Eka Onwardana Institut Sains Dan Teknologi TD.Pardede
  • Harlen Sihotang Institut Sains Dan Teknologi TD.Pardede
  • Swingly Purba Institut Sains Dan Teknologi TD.Pardede

Abstract

Underground coal mining operations require an air supply to mitigate air pollution within the mining area, thereby ensuring the safety and comfort of the workforce. An appropriate ventilation network is essential to distribute air to the areas where it is needed. This study evaluates airflow methods for ventilation and tunnels to determine the most suitable approach for airflow distribution. Testing and analysis of the k-ε, k-ω, and Reynolds Stress models revealed that the k-ε method was the most appropriate. Additionally, the study examines the influence of the distance between the ventilation outlet and the underground mine tunnel wall.

Published
2026-07-16
How to Cite